Prime III UPS (1KVA to 3KVA)

The Prime III UPS protects your sensitive electronic equipment from the most common power problems, including power failures, power sags, power surges, brownouts, line noise, high voltage spikes, frequency variations, switching transients, and harmonic distortion. It is an online double-conversion UPS with scalable runtime, available from 1KVA to 3KVA with unity output power factor.

1KVA to 3KVASingle PhaseRuntime chart & calculator

Description

Power outages might occur unexpectedly and power quality can be erratic. These power problems have the potential to corrupt critical data, destroy unsaved work sessions, and damage hardware, causing hours of lost productivity and expensive repairs. With the UPS, you can safely eliminate the effects of power disturbances and guard the integrity of your equipment.

Reliability: The Prime III UPS maximizes the availability of your IT systems with extended battery duration choices, hot-swappable batteries, internal bypass, and optional maintenance bypass.

More power: The Prime III UPS offers unity output power factor that provides more wattage than a conventional UPS, allowing you to connect more devices.

Efficiency: With up to 90% efficiency rating in normal mode, the double-conversion online Prime III UPS assures high availability and total load protection in its class.

Reduce battery charging time: Batteries may now be charged up to 90% of their capacity in under 8 hours, thanks to the built-in chargers in the UPS and External Battery Pack (EBP).

Simple LCD interface: The simple LCD interface from the Prime III UPS offers a graphical display that gathers all important UPS data in one place. You can read information and change settings with the simple click of a button thanks to the menu’s user-friendly interface.

  • Wide Input Voltage Range: 110-300VAC permits erratic power conditions and minimizes battery transfer.

  • ECO Mode: Through the LCD display, the input voltage regulation range can be adjusted or updated in energy-saving mode.

  • Generator Compatible: Ensures that the loads receive clean, uninterrupted power during a prolonged power outage.

  • Cold Start Function: Enables connected hardware to be started in an emergency when the UPS is not powered.

  • Power Conditioning: Provides protection for connected loads against surges, spikes, lightning, and other power disturbances.

  • Built-in Automatic Bypass: Guarantees uninterrupted power to the load even in the case of a catastrophic UPS failure.

  • Emergency Power Off (EPO): In an emergency, shuts off power to any connected devices right away (optional).

  • Extended Runtime Models Available: Scales runtime from minutes to hours by adding external battery packs, meeting the demands of long duration applications.

  • Easy-to-Cascade External Battery Packs: External Battery Packs (EBP) can be easily cascaded via the back panel battery connector and can be replaced by the user directly.

  • UPS Monitoring: Besides the usual RS232 interface, the UPS can be monitored and controlled via Dry Contact or Ethernet (SNMP) card, using a standard web browser, while providing graceful shutdown for multiple computer systems over the network.
  • Power Rating: 1000 to 3000VA (1000 to 3000W)
  • Power Factor: 1.0
  • Phase: Single phase with ground
  • Input Voltage Range: 110-300Vac
  • Output Voltage: 208/220/230/240Vac (selectable)
  • Frequency: 50/60Hz
  • Input Power Factor: 0.99 with PFC
  • THDv: ≤3% Linear load, ≤5% Non linear load
  • Efficiency up to 90% (AC mode)
  • Waveform: Pure Sinewave
  • Transfer Time: Zero (AC mode to battery mode)
  • Configuration: Tower
  • IEC/EN62040-1, IEC/EN62040-2, and IEC62040-3 Compliance
  • USB (or RS232) Port
  • SNMP Card (Optional)
  • Relay Card (Optional)

Runtime calculator

Enter the load you want to protect, in watts, to see the estimated battery runtime for each model and battery configuration. Add how many hours you need and it will suggest the smallest option that gets there.

Prime III UPS 1KVA (VRLA Batteries)

Move your mouse over the chart to see the runtime at any load.
Configuration10%20%30%40%50%60%70%80%90%100%
Load (W) est.100 W200 W300 W400 W500 W600 W700 W800 W900 W1,000 W
UPS (Std)79 min45 min30 min22 min16 min12 min10 min7 min6 min5 min
UPS (Std) + 1 EBP317 min179 min120 min87 min66 min51 min42 min35 min30 min26 min
UPS (Std) + 2 EBPs559 min348 min229 min161 min125 min97 min80 min67 min57 min50 min
UPS (Std) + 3 EBPs800 min494 min348 min249 min190 min146 min123 min102 min88 min77 min
UPS (Std) + 4 EBPs1068 min684 min469 min348 min258 min202 min165 min140 min120 min105 min

Prime III UPS 1.5KVA (VRLA Batteries)

Move your mouse over the chart to see the runtime at any load.
Configuration10%20%30%40%50%60%70%80%90%100%
Load (W) est.150 W300 W450 W600 W750 W900 W1,050 W1,200 W1,350 W1,500 W
UPS (Std)46 min27 min18 min12 min8 min6 min4 min3 min3 min2 min
UPS (Std) + 1 EBP185 min107 min72 min51 min38 min30 min25 min21 min18 min16 min
UPS (Std) + 2 EBPs348 min202 min137 min97 min74 min59 min48 min40 min35 min30 min
UPS (Std) + 3 EBPs524 min303 min208 min146 min111 min90 min74 min62 min53 min46 min
UPS (Std) + 4 EBPs684 min420 min280 min202 min153 min120 min102 min86 min73 min64 min

Prime III UPS 2KVA (VRLA Batteries)

Move your mouse over the chart to see the runtime at any load.
Configuration10%20%30%40%50%60%70%80%90%100%
Load (W) est.200 W400 W600 W800 W1,000 W1,200 W1,400 W1,600 W1,800 W2,000 W
UPS (Std)78 min45 min30 min21 min16 min12 min10 min7 min6 min5 min
UPS (Std) + 1 EBP303 min174 min118 min86 min65 min51 min42 min35 min30 min26 min
UPS (Std) + 2 EBPs559 min331 min222 min157 min123 min97 min80 min68 min58 min50 min
UPS (Std) + 3 EBPs800 min494 min348 min238 min185 min146 min123 min104 min90 min78 min
UPS (Std) + 4 EBPs1068 min637 min469 min331 min258 min202 min165 min140 min120 min105 min

Prime III UPS 3KVA (VRLA Batteries)

Move your mouse over the chart to see the runtime at any load.
Configuration10%20%30%40%50%60%70%80%90%100%
Load (W) est.300 W600 W900 W1,200 W1,500 W1,800 W2,100 W2,400 W2,700 W3,000 W
UPS (Std)46 min27 min18 min12 min8 min6 min4 min3 min3 min2 min
UPS (Std) + 1 EBP185 min107 min72 min51 min38 min30 min25 min21 min18 min16 min
UPS (Std) + 2 EBPs348 min202 min137 min97 min74 min59 min48 min40 min35 min30 min
UPS (Std) + 3 EBPs524 min303 min208 min146 min111 min90 min74 min62 min53 min46 min
UPS (Std) + 4 EBPs684 min420 min280 min202 min153 min120 min102 min86 min73 min64 min

Runtime figures are typical battery backup times in minutes at the stated load. EBP = External Battery Pack.

Disclaimer: The runtime durations shown above are for reference only. Actual battery backup time may vary depending on the environment in which the UPS is installed, including ambient temperature, battery age and condition, and other site-specific factors.