The Prime III UPS protects your sensitive electronic equipment from the most common power problems, including power failures, power sags, power surges, brownouts, line noise, high voltage spikes, frequency variations, switching transients, and harmonic distortion. It is an online double-conversion UPS with scalable runtime, available from 1KVA to 3KVA with unity output power factor.
1KVA to 3KVASingle PhaseRuntime chart & calculator
Power outages might occur unexpectedly and power quality can be erratic. These power problems have the potential to corrupt critical data, destroy unsaved work sessions, and damage hardware, causing hours of lost productivity and expensive repairs. With the UPS, you can safely eliminate the effects of power disturbances and guard the integrity of your equipment.
Reliability: The Prime III UPS maximizes the availability of your IT systems with extended battery duration choices, hot-swappable batteries, internal bypass, and optional maintenance bypass.
More power: The Prime III UPS offers unity output power factor that provides more wattage than a conventional UPS, allowing you to connect more devices.
Efficiency: With up to 90% efficiency rating in normal mode, the double-conversion online Prime III UPS assures high availability and total load protection in its class.
Reduce battery charging time: Batteries may now be charged up to 90% of their capacity in under 8 hours, thanks to the built-in chargers in the UPS and External Battery Pack (EBP).
Simple LCD interface: The simple LCD interface from the Prime III UPS offers a graphical display that gathers all important UPS data in one place. You can read information and change settings with the simple click of a button thanks to the menu’s user-friendly interface.
Wide Input Voltage Range: 110-300VAC permits erratic power conditions and minimizes battery transfer.
ECO Mode: Through the LCD display, the input voltage regulation range can be adjusted or updated in energy-saving mode.
Generator Compatible: Ensures that the loads receive clean, uninterrupted power during a prolonged power outage.
Cold Start Function: Enables connected hardware to be started in an emergency when the UPS is not powered.
Power Conditioning: Provides protection for connected loads against surges, spikes, lightning, and other power disturbances.
Built-in Automatic Bypass: Guarantees uninterrupted power to the load even in the case of a catastrophic UPS failure.
Emergency Power Off (EPO): In an emergency, shuts off power to any connected devices right away (optional).
Extended Runtime Models Available: Scales runtime from minutes to hours by adding external battery packs, meeting the demands of long duration applications.
Easy-to-Cascade External Battery Packs: External Battery Packs (EBP) can be easily cascaded via the back panel battery connector and can be replaced by the user directly.
UPS Monitoring: Besides the usual RS232 interface, the UPS can be monitored and controlled via Dry Contact or Ethernet (SNMP) card, using a standard web browser, while providing graceful shutdown for multiple computer systems over the network.
Power Rating: 1000 to 3000VA (1000 to 3000W)
Power Factor: 1.0
Phase: Single phase with ground
Input Voltage Range: 110-300Vac
Output Voltage: 208/220/230/240Vac (selectable)
Frequency: 50/60Hz
Input Power Factor: 0.99 with PFC
THDv: ≤3% Linear load, ≤5% Non linear load
Efficiency up to 90% (AC mode)
Waveform: Pure Sinewave
Transfer Time: Zero (AC mode to battery mode)
Configuration: Tower
IEC/EN62040-1, IEC/EN62040-2, and IEC62040-3 Compliance
USB (or RS232) Port
SNMP Card (Optional)
Relay Card (Optional)
Runtime calculator
Enter the load you want to protect, in watts, to see the estimated battery runtime for each model and battery configuration. Add how many hours you need and it will suggest the smallest option that gets there.
Prime III UPS 1KVA (VRLA Batteries)
Move your mouse over the chart to see the runtime at any load.
Configuration
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Load (W) est.
100 W
200 W
300 W
400 W
500 W
600 W
700 W
800 W
900 W
1,000 W
UPS (Std)
79 min
45 min
30 min
22 min
16 min
12 min
10 min
7 min
6 min
5 min
UPS (Std) + 1 EBP
317 min
179 min
120 min
87 min
66 min
51 min
42 min
35 min
30 min
26 min
UPS (Std) + 2 EBPs
559 min
348 min
229 min
161 min
125 min
97 min
80 min
67 min
57 min
50 min
UPS (Std) + 3 EBPs
800 min
494 min
348 min
249 min
190 min
146 min
123 min
102 min
88 min
77 min
UPS (Std) + 4 EBPs
1068 min
684 min
469 min
348 min
258 min
202 min
165 min
140 min
120 min
105 min
Prime III UPS 1.5KVA (VRLA Batteries)
Move your mouse over the chart to see the runtime at any load.
Configuration
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Load (W) est.
150 W
300 W
450 W
600 W
750 W
900 W
1,050 W
1,200 W
1,350 W
1,500 W
UPS (Std)
46 min
27 min
18 min
12 min
8 min
6 min
4 min
3 min
3 min
2 min
UPS (Std) + 1 EBP
185 min
107 min
72 min
51 min
38 min
30 min
25 min
21 min
18 min
16 min
UPS (Std) + 2 EBPs
348 min
202 min
137 min
97 min
74 min
59 min
48 min
40 min
35 min
30 min
UPS (Std) + 3 EBPs
524 min
303 min
208 min
146 min
111 min
90 min
74 min
62 min
53 min
46 min
UPS (Std) + 4 EBPs
684 min
420 min
280 min
202 min
153 min
120 min
102 min
86 min
73 min
64 min
Prime III UPS 2KVA (VRLA Batteries)
Move your mouse over the chart to see the runtime at any load.
Configuration
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Load (W) est.
200 W
400 W
600 W
800 W
1,000 W
1,200 W
1,400 W
1,600 W
1,800 W
2,000 W
UPS (Std)
78 min
45 min
30 min
21 min
16 min
12 min
10 min
7 min
6 min
5 min
UPS (Std) + 1 EBP
303 min
174 min
118 min
86 min
65 min
51 min
42 min
35 min
30 min
26 min
UPS (Std) + 2 EBPs
559 min
331 min
222 min
157 min
123 min
97 min
80 min
68 min
58 min
50 min
UPS (Std) + 3 EBPs
800 min
494 min
348 min
238 min
185 min
146 min
123 min
104 min
90 min
78 min
UPS (Std) + 4 EBPs
1068 min
637 min
469 min
331 min
258 min
202 min
165 min
140 min
120 min
105 min
Prime III UPS 3KVA (VRLA Batteries)
Move your mouse over the chart to see the runtime at any load.
Configuration
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Load (W) est.
300 W
600 W
900 W
1,200 W
1,500 W
1,800 W
2,100 W
2,400 W
2,700 W
3,000 W
UPS (Std)
46 min
27 min
18 min
12 min
8 min
6 min
4 min
3 min
3 min
2 min
UPS (Std) + 1 EBP
185 min
107 min
72 min
51 min
38 min
30 min
25 min
21 min
18 min
16 min
UPS (Std) + 2 EBPs
348 min
202 min
137 min
97 min
74 min
59 min
48 min
40 min
35 min
30 min
UPS (Std) + 3 EBPs
524 min
303 min
208 min
146 min
111 min
90 min
74 min
62 min
53 min
46 min
UPS (Std) + 4 EBPs
684 min
420 min
280 min
202 min
153 min
120 min
102 min
86 min
73 min
64 min
Runtime figures are typical battery backup times in minutes at the stated load. EBP = External Battery Pack.
Disclaimer: The runtime durations shown above are for reference only. Actual battery backup time may vary depending on the environment in which the UPS is installed, including ambient temperature, battery age and condition, and other site-specific factors.
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.