Elite V RT Li UPS Rack/Tower Convertible (6KVA to 10KVA) New
The Elite V RT Li UPS is engineered for high-performance in mission-critical environments, particularly within the 6–10kVA range that runs on either VRLA batteries or Lithium Batteries. Its robust design includes full-spectrum protection—covering overload, low battery, abnormal input, short circuits, and thermal risks—while delivering pure sine wave output for stable power. It’s an ideal solution for industries such as finance, telecom, healthcare, manufacturing, and enterprise IT.
6KVA to 10KVASingle PhaseRack / Tower convertibleRuntime chart & calculator
As today’s infrastructure increasingly demands compact, efficient, and intelligent backup power solutions, PowerHub Elite V RT Li UPS systems have become a leading alternative to conventional lead-acid UPS units. By integrating lithium battery technology and smart management systems, these UPS solutions redefine reliability during power disruptions.
Input Line to Line (L-L-GND) or Line to Neutral (L-N-GND) Configuration
Wide input voltage range: 110~300Vac
N+X parallel redundancy up to 4 units
Online double conversion with DSP control
3-level inverter topology, boosting efficiency to as high as 95.5%
Input current harmonics < 3%
High output power factor at 1.0
Intelligent fan speed regulation
Multiple protection function: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage and fan fault alarm
Communication port: USB, Dry contact, RS485
Optional SNMP card / Relay Card
Input Voltage: 110–300 Vac (supports L-L-GND and L-N-GND)
IEC / EN 62040-3 (Performance and Test Requirements)
Runtime calculator
Enter the load you want to protect, in watts, to see the estimated battery runtime for each model and battery configuration. Add how many hours you need and it will suggest the smallest option that gets there.
Elite V RT Li 6KVA (VRLA Batteries)
Move your mouse over the chart to see the runtime at any load.
Configuration
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Load (W) est.
600 W
1,200 W
1,800 W
2,400 W
3,000 W
3,600 W
4,200 W
4,800 W
5,400 W
6,000 W
UPS (Ext)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
UPS (Ext) + 1 EBP
133 min
60 min
36 min
26 min
19 min
15 min
12 min
10 min
8 min
6 min
UPS (Ext) + 2 EBPs
318 min
142 min
87 min
61 min
46 min
37 min
30 min
26 min
22 min
19 min
UPS (Ext) + 3 EBPs
520 min
237 min
142 min
102 min
78 min
61 min
50 min
43 min
37 min
32 min
UPS (Ext) + 4 EBPs
682 min
346 min
207 min
145 min
112 min
90 min
72 min
61 min
53 min
46 min
UPS (Ext) + 5 EBPs
876 min
441 min
280 min
189 min
145 min
116 min
97 min
81 min
70 min
61 min
Elite V RT Li 10KVA (VRLA Batteries)
Move your mouse over the chart to see the runtime at any load.
Configuration
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Load (W) est.
1,000 W
2,000 W
3,000 W
4,000 W
5,000 W
6,000 W
7,000 W
8,000 W
9,000 W
10,000 W
UPS (Ext)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
UPS (Ext) + 1 EBP
73 min
32 min
19 min
13 min
9 min
6 min
5 min
4 min
4 min
3 min
UPS (Ext) + 2 EBPs
174 min
76 min
46 min
32 min
25 min
19 min
16 min
13 min
11 min
9 min
UPS (Ext) + 3 EBPs
292 min
125 min
78 min
54 min
41 min
33 min
27 min
23 min
19 min
17 min
UPS (Ext) + 4 EBPs
417 min
179 min
112 min
78 min
58 min
47 min
39 min
33 min
28 min
24 min
UPS (Ext) + 5 EBPs
520 min
237 min
145 min
102 min
78 min
62 min
50 min
43 min
37 min
32 min
Elite V RT Li 6KVA (Lithium Batteries)
Move your mouse over the chart to see the runtime at any load.
Configuration
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Load (W) est.
600 W
1,200 W
1,800 W
2,400 W
3,000 W
3,600 W
4,200 W
4,800 W
5,400 W
6,000 W
UPS (Ext)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
UPS (Ext) + 1 EBP
165 min
82 min
55 min
41 min
33 min
27 min
23 min
19 min
17 min
15 min
UPS (Ext) + 2 EBPs
331 min
165 min
110 min
82 min
66 min
55 min
47 min
40 min
35 min
32 min
UPS (Ext) + 3 EBPs
497 min
248 min
165 min
124 min
99 min
82 min
71 min
61 min
54 min
48 min
UPS (Ext) + 4 EBPs
663 min
331 min
221 min
165 min
132 min
110 min
94 min
81 min
72 min
65 min
Elite V RT Li 10KVA (Lithium Batteries)
Move your mouse over the chart to see the runtime at any load.
Configuration
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Load (W) est.
1,000 W
2,000 W
3,000 W
4,000 W
5,000 W
6,000 W
7,000 W
8,000 W
9,000 W
10,000 W
UPS (Ext)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
UPS (Ext) + 1 EBP
99 min
49 min
33 min
24 min
19 min
16 min
14 min
11 min
10 min
8 min
UPS (Ext) + 2 EBPs
199 min
99 min
66 min
49 min
39 min
33 min
28 min
23 min
21 min
18 min
UPS (Ext) + 3 EBPs
298 min
149 min
99 min
74 min
59 min
49 min
42 min
36 min
32 min
28 min
UPS (Ext) + 4 EBPs
398 min
199 min
132 min
99 min
79 min
66 min
56 min
48 min
43 min
38 min
Compare: VRLA vs Lithium Batteries
VRLA means valve-regulated lead-acid (sealed lead-acid) batteries. For the same number of external battery packs (EBPs), the lithium option gives a longer runtime – for example, at 50% load with 2 EBPs, about 50% longer (6KVA: 46 min VRLA vs 66 min lithium; 10KVA: 25 min VRLA vs 39 min lithium). Use the selector below to compare at any load.
Runtime figures are typical battery backup times in minutes at the stated load. EBP = External Battery Pack.
Disclaimer: The runtime durations shown above are for reference only. Actual battery backup time may vary depending on the environment in which the UPS is installed, including ambient temperature, battery age and condition, and other site-specific factors.