Home|Products|Uninterruptible Power Supply (UPS)|Single Phase UPS|Elite V RT Li UPS Rack/Tower Convertible (6KVA to 10KVA) New

Elite V RT Li UPS Rack/Tower Convertible (6KVA to 10KVA) New

The Elite V RT Li UPS is engineered for high-performance in mission-critical environments, particularly within the 6–10kVA range that runs on either VRLA batteries or Lithium Batteries. Its robust design includes full-spectrum protection—covering overload, low battery, abnormal input, short circuits, and thermal risks—while delivering pure sine wave output for stable power. It’s an ideal solution for industries such as finance, telecom, healthcare, manufacturing, and enterprise IT.

6KVA to 10KVASingle PhaseRack / Tower convertibleRuntime chart & calculator

Description

As today’s infrastructure increasingly demands compact, efficient, and intelligent backup power solutions, PowerHub Elite V RT Li UPS systems have become a leading alternative to conventional lead-acid UPS units. By integrating lithium battery technology and smart management systems, these UPS solutions redefine reliability during power disruptions.

  • Input Line to Line (L-L-GND) or Line to Neutral (L-N-GND) Configuration
  • Wide input voltage range: 110~300Vac
  • N+X parallel redundancy up to 4 units
  • Online double conversion with DSP control
  • 3-level inverter topology, boosting efficiency to as high as 95.5%
  • Input current harmonics < 3%
  • High output power factor at 1.0
  • Intelligent fan speed regulation
  • Multiple protection function: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage and fan fault alarm
  • Communication port: USB, Dry contact, RS485
  • Optional SNMP card / Relay Card
  • Input Voltage: 110–300 Vac (supports L-L-GND and L-N-GND)
  • Input Frequency: 40–70 Hz (auto sensing)
  • Input Power Factor: ≥ 0.99
  • Input Current Harmonics: ≤ 3%
  • Output Voltage: 208 / 220 / 230 / 240 Vac selectable
  • Output Frequency: 50 / 60 Hz selectable
  • Output Power Factor: 1.0
  • Voltage Regulation: ±1% (online mode)
  • Topology: Online double conversion with DSP control
  • Inverter Design: 3-level inverter topology
  • Efficiency: Up to 95.5% (up to 99% in ECO mode)
  • Parallel Capability: N+X redundancy, up to 4 units
  • Transfer Time: 0 ms (online to battery)
  • Battery DC Voltage: 192 Vdc
  • Charging Current: Up to 12 A
  • Protection Features: Short-circuit, overload, overheat, battery overcharge & over-discharge, output low voltage, fan fault
  • Communication Interfaces: USB, Dry Contact, RS485
  • Optional Accessories: SNMP card, Relay card
  • Cooling: Intelligent fan speed regulation
  • Operating Temperature: 0°C to 40°C
  • Noise Level: ≤ 55 dB @ 1 meter
  • Standards Compliance:
    • IEC / EN 62040-1 (Safety Requirements)
    • IEC / EN 62040-2 (EMC Requirements)
    • IEC / EN 62040-3 (Performance and Test Requirements)

Runtime calculator

Enter the load you want to protect, in watts, to see the estimated battery runtime for each model and battery configuration. Add how many hours you need and it will suggest the smallest option that gets there.

Elite V RT Li 6KVA (VRLA Batteries)

Move your mouse over the chart to see the runtime at any load.
Configuration10%20%30%40%50%60%70%80%90%100%
Load (W) est.600 W1,200 W1,800 W2,400 W3,000 W3,600 W4,200 W4,800 W5,400 W6,000 W
UPS (Ext)N/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
UPS (Ext) + 1 EBP133 min60 min36 min26 min19 min15 min12 min10 min8 min6 min
UPS (Ext) + 2 EBPs318 min142 min87 min61 min46 min37 min30 min26 min22 min19 min
UPS (Ext) + 3 EBPs520 min237 min142 min102 min78 min61 min50 min43 min37 min32 min
UPS (Ext) + 4 EBPs682 min346 min207 min145 min112 min90 min72 min61 min53 min46 min
UPS (Ext) + 5 EBPs876 min441 min280 min189 min145 min116 min97 min81 min70 min61 min

Elite V RT Li 10KVA (VRLA Batteries)

Move your mouse over the chart to see the runtime at any load.
Configuration10%20%30%40%50%60%70%80%90%100%
Load (W) est.1,000 W2,000 W3,000 W4,000 W5,000 W6,000 W7,000 W8,000 W9,000 W10,000 W
UPS (Ext)N/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
UPS (Ext) + 1 EBP73 min32 min19 min13 min9 min6 min5 min4 min4 min3 min
UPS (Ext) + 2 EBPs174 min76 min46 min32 min25 min19 min16 min13 min11 min9 min
UPS (Ext) + 3 EBPs292 min125 min78 min54 min41 min33 min27 min23 min19 min17 min
UPS (Ext) + 4 EBPs417 min179 min112 min78 min58 min47 min39 min33 min28 min24 min
UPS (Ext) + 5 EBPs520 min237 min145 min102 min78 min62 min50 min43 min37 min32 min

Elite V RT Li 6KVA (Lithium Batteries)

Move your mouse over the chart to see the runtime at any load.
Configuration10%20%30%40%50%60%70%80%90%100%
Load (W) est.600 W1,200 W1,800 W2,400 W3,000 W3,600 W4,200 W4,800 W5,400 W6,000 W
UPS (Ext)N/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
UPS (Ext) + 1 EBP165 min82 min55 min41 min33 min27 min23 min19 min17 min15 min
UPS (Ext) + 2 EBPs331 min165 min110 min82 min66 min55 min47 min40 min35 min32 min
UPS (Ext) + 3 EBPs497 min248 min165 min124 min99 min82 min71 min61 min54 min48 min
UPS (Ext) + 4 EBPs663 min331 min221 min165 min132 min110 min94 min81 min72 min65 min

Elite V RT Li 10KVA (Lithium Batteries)

Move your mouse over the chart to see the runtime at any load.
Configuration10%20%30%40%50%60%70%80%90%100%
Load (W) est.1,000 W2,000 W3,000 W4,000 W5,000 W6,000 W7,000 W8,000 W9,000 W10,000 W
UPS (Ext)N/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
UPS (Ext) + 1 EBP99 min49 min33 min24 min19 min16 min14 min11 min10 min8 min
UPS (Ext) + 2 EBPs199 min99 min66 min49 min39 min33 min28 min23 min21 min18 min
UPS (Ext) + 3 EBPs298 min149 min99 min74 min59 min49 min42 min36 min32 min28 min
UPS (Ext) + 4 EBPs398 min199 min132 min99 min79 min66 min56 min48 min43 min38 min

Compare: VRLA vs Lithium Batteries

VRLA means valve-regulated lead-acid (sealed lead-acid) batteries. For the same number of external battery packs (EBPs), the lithium option gives a longer runtime – for example, at 50% load with 2 EBPs, about 50% longer (6KVA: 46 min VRLA vs 66 min lithium; 10KVA: 25 min VRLA vs 39 min lithium). Use the selector below to compare at any load.

Runtime figures are typical battery backup times in minutes at the stated load. EBP = External Battery Pack.

Disclaimer: The runtime durations shown above are for reference only. Actual battery backup time may vary depending on the environment in which the UPS is installed, including ambient temperature, battery age and condition, and other site-specific factors.

Similar models

Got a Question?

Feel free to contact us if you have any queries.