THREE PHASE UPS

Delta Modulon DPH

The Modulon DPH Series UPS is a modular UPS used extensively for critical operations, since it provides 25% more power output compared to power factor 0.8 UPS systems. Designed for the most stringent data center requirements, the Modulon DPH Series offers the highest possible availability. With its modular structure, the true on-line, double conversion, three-phase Modulon DPH Series UPS system offers a scalable architecture for optimal power designs. It provides 25kW to 200kW of uninterruptible power with additional 800kW capacity in parallel.

Built-in redundancy guarantees a continued power supply for mission critical applications, and the fully fault-tolerant design of the Modulon DPH Series offers self-redundancy for the control mechanism, cooling and power modules. Mean time to repair (MTTR) is close to zero, due to hot-swappable functionality for all critical components. In the event of failure by the main module, full control logic enables the system to self-synchronize and switch to the backup, for a seamless transition with no disruption to operations.

Delta’s Modulon DPH Series UPS provides one of the highest efficiency ratings in its class. With fully rated power, this modular 3 phase UPS delivers maximum power capacity, better power protection and quality to the load. Scalability, availability, and efficiency distinguish the Modulon DPH Series UPS as the best solution for power protection and distribution in your data centers.

 

  • Advanced fault-tolerant design achieved by self redundancy to guarantee operation continuity.
  • Self-synchronization of power and control modules for continuous on-line operation even in the event of control module failure to avoid downtime caused by single point failure.
  • Hot-swappable key modules and components to ensure Mean Time To Repair (MTTR) close to zero without downtime risk.
  •  Vertical expansion from 25kW to 75/150/200kW supporting N+X redundancy in a single rack enclosure to save footprint.
  • Parallel expansion up to four units without requiring additional hardware.
  • Variable configurations possible providing the scalable flexibility up to Tier 4 standard.
  • Fully rated power (kVA=kW) to maximize power availability.
  • Low harmonic pollution (iTHD<3%) to reduce upstream investment costs and meet demanding power requirements.
  • Built-in manual bypass features to eliminate maintenance-related downtime.
  • Proactive detection of fan failure and switch fault for early diagnosis on UPS malfunction.
  • Plug and play to simplify the maintenance process